EAVZ16S23DA6V / EPGA11DAV3 |
EAVZ16S18DA6V / EPGA11DAV3 |
EAVZ16S23DA6V / EPGA14DAV3 |
EAVZ16S18DA6V / EPGA14DAV3 |
EAVZ16S18DA6V / EPGA16DAV3 |
EAVZ16S23DA6V / EPGA16DAV3 |
Εσωτερική μονάδα |
EAVZ16S23DA6V |
EAVZ16S18DA6V |
EAVZ16S23DA6V |
EAVZ16S18DA6V |
EAVZ16S18DA6V |
EAVZ16S23DA6V |
Εξωτερική μονάδα |
EPGA11DAV3 |
EPGA11DAV3 |
EPGA14DAV3 |
EPGA14DAV3 |
EPGA16DAV3 |
EPGA16DAV3 |
Απόδοση θέρμανσης |
Ονομ. |
kW |
11.1 (1), 11.3 (2) |
11.1 (1), 11.3 (2) |
14.5 (1), 14.5 (2) |
14.5 (1), 14.5 (2) |
16.5 (1), 15.6 (2) |
16.5 (1), 15.6 (2) |
Ισχύς εισόδου |
Θέρμανση |
Ονομ. |
kW |
2.16 (1), 2.91 (2) |
2.16 (1), 2.91 (2) |
2.91 (1), 3.96 |
2.91 (1), 3.96 |
3.45 (1), 4.21 (2) |
3.45 (1), 4.21 (2) |
|
Ζεστό νερό χρήσης από 10°C έως 50°C |
Ονομ. |
kWh |
3.08 |
2.67 |
3.08 |
2.67 |
2.67 |
3.08 |
Heat up time from 10°C to 50°C |
hr |
1h02min at 7°C ambient temperature |
53min at 7°C ambient temperature |
1h02min at 7°C ambient temperature |
53min at 7°C ambient temperature |
53min at 7°C ambient temperature |
1h02min at 7°C ambient temperature |
COP |
5.15 (1), 3.88 (2) |
5.15 (1), 3.88 (2) |
4.99 (1), 3.65 (2) |
4.99 (1), 3.65 (2) |
4.78 (1), 3.71 (2) |
4.78 (1), 3.71 (2) |
Αντλία |
Type |
|
Grundfos UPML GEO 25-105 130 PWM |
Grundfos UPML GEO 25-105 130 PWM |
Grundfos UPML GEO 25-105 130 PWM |
Grundfos UPML GEO 25-105 130 PWM |
Grundfos UPML GEO 25-105 130 PWM |
Grundfos UPML GEO 25-105 130 PWM |
Επιπρόσθετη ζώνη αντλίας |
Τύπος |
|
Βλ. σημείωση 13, Βλ. σημείωση 14 |
Βλ. σημείωση 13, Βλ. σημείωση 14 |
Βλ. σημείωση 11, Βλ. σημείωση 12 |
Βλ. σημείωση 11, Βλ. σημείωση 12 |
Βλ. σημείωση 1, Βλ. σημείωση 10 |
Βλ. σημείωση 1, Βλ. σημείωση 10 |
Κύρια ζώνη αντλίας |
Τύπος |
|
Βλ. σημείωση 13, Βλ. σημείωση 14 |
Βλ. σημείωση 13, Βλ. σημείωση 14 |
Βλ. σημείωση 11, Βλ. σημείωση 12 |
Βλ. σημείωση 11, Βλ. σημείωση 12 |
Βλ. σημείωση 1, Βλ. σημείωση 10 |
Βλ. σημείωση 1, Βλ. σημείωση 10 |
Πλευρικός εναλλάκτης θερμότητας νερού |
Ταχύτητα ροής νερού |
Θέρμανση |
Ονομ. |
l/min |
32.5 (1), 32.4 (2) |
32.5 (1), 32.4 (2) |
41.2 (1), 41.5 (2) |
41.2 (1), 41.5 (2) |
45.1 (1), 44.7 (2) |
45.1 (1), 44.7 (2) |
Γενικά |
Λεπτομέρειες προμηθευτή/κατασκευαστή |
Όνομα και διεύθυνση |
|
Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium |
Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium |
Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium |
Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium |
Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium |
Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium |
|
|
Ονομασία ή εμπορικό σήμα |
|
Daikin Europe N.V. |
Daikin Europe N.V. |
Daikin Europe N.V. |
Daikin Europe N.V. |
Daikin Europe N.V. |
Daikin Europe N.V. |
|
Περιγραφή προϊόντος |
Αντλία θερμότητας αέρα σε νερό |
|
Ναι |
Ναι |
Ναι |
Ναι |
Ναι |
Ναι |
|
|
Αντλία θερμότητας άλμης σε νερό |
|
όχι |
όχι |
όχι |
όχι |
όχι |
όχι |
|
|
Θερμαντήρας συνδυασμού αντλίας θερμότητας |
|
Ναι |
Ναι |
Ναι |
Ναι |
Ναι |
Ναι |
|
|
Αντλία θερμότητας χαμηλής θερμοκρασίας |
|
όχι |
όχι |
όχι |
όχι |
όχι |
όχι |
|
|
Συμπληρωματικός ενσωματωμένος θερμαντήρας |
|
Ναι |
Ναι |
Ναι |
Ναι |
Ναι |
Ναι |
|
|
Αντλία θερμότητας νερό σε νερό |
|
όχι |
όχι |
όχι |
όχι |
όχι |
όχι |
|
LW(A) Στάθμη ηχητικής ισχύoς (σύμφωνη με το EN14825) |
Εσωτερικός χώρος |
dB(A) |
44.0 |
44.0 |
44.0 |
44.0 |
44.0 |
44.0 |
LW(A) Στάθμη ηχητικής ισχύoς (σύμφωνα με το ΕΝ14825) |
Εξωτερικός χώρος |
dB(A) |
64.0 |
64.0 |
64.0 |
64.0 |
66.0 |
66.0 |
Προϋποθέσεις θορύβου οικολογικού σχεδιασμού και ενεργειακή σήμανση |
Ηχητικής ισχύς στη λειτουργία θέρμανσης, μετρημένη σύμφωνα με το ΕΝ12102 υπό τις συνθήκες του ΕΝ14825 |
Ηχητικής ισχύς στη λειτουργία θέρμανσης, μετρημένη σύμφωνα με το ΕΝ12102 υπό τις συνθήκες του ΕΝ14825 |
Ηχητικής ισχύς στη λειτουργία θέρμανσης, μετρημένη σύμφωνα με το ΕΝ12102 υπό τις συνθήκες του ΕΝ14825 |
Ηχητικής ισχύς στη λειτουργία θέρμανσης, μετρημένη σύμφωνα με το ΕΝ12102 υπό τις συνθήκες του ΕΝ14825 |
Ηχητικής ισχύς στη λειτουργία θέρμανσης, μετρημένη σύμφωνα με το ΕΝ12102 υπό τις συνθήκες του ΕΝ14825 |
Ηχητικής ισχύς στη λειτουργία θέρμανσης, μετρημένη σύμφωνα με το ΕΝ12102 υπό τις συνθήκες του ΕΝ14825 |
Θέρμανση χώρου γενικά |
Μονάδα αέρα σε νερό |
Ονομαστική ροή αέρα (εξωτερικός χώρος) |
m³/ώρα |
6,900 |
6,900 |
6,900 |
6,900 |
8,100 |
8,100 |
|
Άλλο |
Έλεγχος απόδοσης |
|
Inverter |
Inverter |
Inverter |
Inverter |
Inverter |
Inverter |
|
|
Pck (λειτουργία θερμαντήρα στροφαλοθαλάμου) |
kW |
0.000 |
0.000 |
0.000 |
0.000 |
0.000 |
0.000 |
|
|
Poff (λειτουργία εκτός) |
kW |
0.021 |
0.021 |
0.021 |
0.021 |
0.021 |
0.021 |
|
|
Psb (λειτουργία ετοιμότητας) |
kW |
0.021 |
0.021 |
0.021 |
0.021 |
0.021 |
0.021 |
|
|
Pto (θερμοστάτης εκτός) |
kW |
0.041 |
0.041 |
0.041 |
0.041 |
0.041 |
0.041 |
|
Ενσωματωμένος συμπληρωματικός θερμαντήρας |
Psup |
kW |
6.0 |
6.0 |
6.0 |
6.0 |
6.0 |
6.0 |
|
|
Τύπος εισόδου ενέργειας |
|
Ηλεκτρολογικά |
Ηλεκτρολογικά |
Ηλεκτρολογικά |
Ηλεκτρολογικά |
Ηλεκτρολογικά |
Ηλεκτρολογικά |
Θέρμανση ζεστού νερού χρήσης |
Γενικά |
Δηλωμένο προφίλ φορτίου |
|
XL |
L |
XL |
L |
L |
XL |
|
|
Λειτουργία για την ρύθμιση της θέρμανσης νερού κατά τη διάρκεια των ωρών εκτός αιχμής |
|
Ναι |
Ναι |
Ναι |
Ναι |
Ναι |
Ναι |
|
Μέσο κλίμα |
AEC (ετήσια κατανάλωση ηλεκτρικού ρεύματος) |
kWh |
1,513 |
1,029 |
1,513 |
1,029 |
1,029 |
1,513 |
|
|
AFC (Ετήσια κατανάλωση καυσίμου) |
Gj |
5.45 |
3.70 |
5.45 |
3.70 |
3.70 |
5.45 |
|
|
Ƞwh (απόδοση θέρμανσης νερού) |
% |
112 |
104 |
112 |
104 |
104 |
112 |
|
|
Qelec (ημερήσια κατανάλωση ηλεκτρικού ρεύματος) |
kWh |
7.090 |
4.870 |
7.090 |
4.870 |
4.870 |
7.090 |
|
|
Κατηγορία ενεργειακής απόδοσης θέρμανσης νερού |
|
A |
A |
A |
A |
A |
A |
|
Ψυχρό κλίμα |
AEC (ετήσια κατανάλωση ηλεκτρικού ρεύματος) |
kWh |
1,851 |
1,066 |
1,851 |
1,066 |
1,066 |
1,851 |
|
|
AFC (ετήσια κατανάλωση καυσίμου) |
Gj |
6.66 |
3.84 |
6.66 |
3.84 |
3.84 |
6.66 |
|
|
Ƞwh (απόδοση θέρμανσης νερού) |
% |
91 |
100 |
91 |
100 |
100 |
91 |
|
|
Qelec (ημερήσια κατανάλωση ηλεκτρικού ρεύματος) |
kWh |
8.850 |
5.195 |
8.850 |
5.195 |
5.195 |
8.850 |
|
Θερμό κλίμα |
AEC (ετήσια κατανάλωση ηλεκτρικού ρεύματος) |
kWh |
1,301 |
749 |
1,301 |
749 |
749 |
1,301 |
|
|
AFC (ετήσια κατανάλωση καυσίμου) |
Gj |
4.68 |
2.70 |
4.68 |
2.70 |
2.70 |
4.68 |
|
|
Ƞwh (απόδοση θέρμανσης νερού) |
% |
130 |
142 |
130 |
142 |
142 |
130 |
|
|
Qelec (ημερήσια κατανάλωση ηλεκτρικού ρεύματος) |
kWh |
6.160 |
3.590 |
6.160 |
3.590 |
3.590 |
6.160 |
Θέρμανση χώρου |
Εξαγωγή νερού μέσου κλίματος 55°C |
Γενικά |
Ετήσια κατανάλωση ενέργειας |
kWh |
7,845 |
7,845 |
8,669 |
8,669 |
9,706 |
9,706 |
|
|
|
Εποχιακή απόδοση θέρμανσης χώρου |
% |
129 |
129 |
130 |
130 |
133 |
133 |
|
|
|
Prated στους -10°C |
kW |
13 |
13 |
14 |
14 |
16 |
16 |
|
|
|
Qhe Ετήσια κατανάλωση ενέργειας (GCV) |
Gj |
28.2 |
28.2 |
31.2 |
31.2 |
34.9 |
34.9 |
|
|
|
SCOP |
|
3.29 |
3.29 |
3.34 |
3.34 |
3.41 |
3.41 |
|
|
|
Κατηγορία εποχιακής απόδοσης θέρμανσης χώρου |
|
A++ |
A++ |
A++ |
A++ |
A++ |
A++ |
|
|
A Συνθήκες (-7°CDB/-8°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
|
|
|
COPd |
|
2.25 |
2.25 |
2.17 |
2.17 |
2.23 |
2.23 |
|
|
|
Pdh |
kW |
11.5 |
11.5 |
12.3 |
12.3 |
13.1 |
13.1 |
|
|
|
PERd |
% |
90.0 |
90.0 |
86.8 |
86.8 |
89.2 |
89.2 |
|
|
Προϋπόθεση Β (2°CDB/1°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
|
|
|
COPd |
|
3.14 |
3.14 |
3.18 |
3.18 |
3.26 |
3.26 |
|
|
|
Pdh |
kW |
6.5 |
6.5 |
8.1 |
8.1 |
8.7 |
8.7 |
|
|
|
PERd |
% |
125.6 |
125.6 |
127.2 |
127.2 |
130.4 |
130.4 |
|
|
C Συνθήκες (7°CDB/6°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
0.96 |
0.96 |
1.0 |
1.0 |
1.0 |
1.0 |
|
|
|
COPd |
|
4.27 |
4.27 |
4.46 |
4.46 |
4.62 |
4.62 |
|
|
|
Pdh |
kW |
4.6 |
4.6 |
5.0 |
5.0 |
5.8 |
5.8 |
|
|
|
PERd |
% |
170.8 |
170.8 |
178.4 |
178.4 |
184.8 |
184.8 |
|
|
Προϋπόθεση D (12°CDB/11°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
0.95 |
0.95 |
0.95 |
0.95 |
0.95 |
0.95 |
|
|
|
COPd |
|
5.75 |
5.75 |
5.94 |
5.94 |
6.47 |
6.47 |
|
|
|
Pdh |
kW |
5.2 |
5.2 |
5.2 |
5.2 |
5.2 |
5.2 |
|
|
|
PERd |
% |
230.0 |
230.0 |
237.6 |
237.6 |
258.8 |
258.8 |
|
|
Tol (όριο θερμοκρασίας λειτουργίας) |
COPd |
|
2.11 |
2.11 |
2.10 |
2.10 |
2.05 |
2.05 |
|
|
|
Pdh |
kW |
12.5 |
12.5 |
13.5 |
13.5 |
13.2 |
13.2 |
|
|
|
PERd |
% |
84.4 |
84.4 |
84.0 |
84.0 |
82.0 |
82.0 |
|
|
|
TOL |
°C |
-10 |
-10 |
-10 |
-10 |
-10 |
-10 |
|
|
|
WTOL |
°C |
55 |
55 |
55 |
55 |
55 |
55 |
|
|
Ονομ. θερμική ισχύς, συμπληρ. απόδοση |
Psup (σε Tdesign -10°C) |
kW |
0.0 |
0.0 |
0.5 |
0.5 |
2.8 |
2.8 |
|
|
Tbiv (δισθενής θερμοκρασία) |
COPd |
|
2.11 |
2.11 |
2.17 |
2.17 |
2.40 |
2.40 |
|
|
|
Pdh |
kW |
12.5 |
12.5 |
12.3 |
12.3 |
12.9 |
12.9 |
|
|
|
PERd |
% |
84.4 |
84.4 |
86.8 |
86.8 |
96.0 |
96.0 |
|
|
|
Tbiv |
°C |
-10 |
-10 |
-7 |
-7 |
-5 |
-5 |
|
Εξαγωγή νερού ψυχρού κλίματος 55°C |
Γενικά |
Ετήσια κατανάλωση ενέργειας |
kWh |
10,085 |
10,085 |
11,385 |
11,385 |
12,295 |
12,295 |
|
|
|
Εποχιακή απόδοση θέρμανσης χώρου |
% |
124 |
124 |
123 |
123 |
121 |
121 |
|
|
|
Prated στους -22°C |
kW |
13 |
13 |
15 |
15 |
15 |
15 |
|
|
|
Qhe Ετήσια κατανάλωση ενέργειας (GCV) |
Gj |
36.3 |
36.3 |
41.0 |
41.0 |
44.3 |
44.3 |
|
|
A Συνθήκες (-7°CDB/-8°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
|
|
|
COPd |
|
2.68 |
2.68 |
2.61 |
2.61 |
2.58 |
2.58 |
|
|
|
Pdh |
kW |
8.3 |
8.3 |
8.8 |
8.8 |
9.4 |
9.4 |
|
|
|
PERd |
% |
107.2 |
107.2 |
104.4 |
104.4 |
103.2 |
103.2 |
|
|
Προϋπόθεση Β (2°CDB/1°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
|
|
|
COPd |
|
3.75 |
3.75 |
3.75 |
3.75 |
3.66 |
3.66 |
|
|
|
Pdh |
kW |
5.1 |
5.1 |
5.5 |
5.5 |
5.9 |
5.9 |
|
|
|
PERd |
% |
150.0 |
150.0 |
150.0 |
150.0 |
146.4 |
146.4 |
|
|
Προϋπόθεση C (7°CDB/6°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
0.96 |
0.96 |
0.96 |
0.96 |
0.96 |
0.96 |
|
|
|
COPd |
|
4.63 |
4.63 |
4.70 |
4.70 |
4.75 |
4.75 |
|
|
|
Pdh |
kW |
4.5 |
4.5 |
4.5 |
4.5 |
4.5 |
4.5 |
|
|
|
PERd |
% |
185.2 |
185.2 |
188.0 |
188.0 |
190.0 |
190.0 |
|
|
D Συνθήκες (12°CDB/11°CWB) |
COPd |
|
6.01 |
6.01 |
6.13 |
6.13 |
6.21 |
6.21 |
|
|
|
Pdh |
kW |
5.2 |
5.2 |
5.2 |
5.2 |
5.1 |
5.1 |
|
|
|
PERd |
% |
240.4 |
240.4 |
245.2 |
245.2 |
248.4 |
248.4 |
|
|
Tol (όριο θερμοκρασίας λειτουργίας) |
COPd |
|
1.34 |
1.34 |
1.34 |
1.34 |
1.34 |
1.34 |
|
|
|
Pdh |
kW |
7.5 |
7.5 |
7.5 |
7.5 |
7.5 |
7.5 |
|
|
|
PERd |
% |
53.6 |
53.6 |
53.6 |
53.6 |
53.6 |
53.6 |
|
|
|
TOL |
°C |
-21 |
-21 |
-21 |
-21 |
-21 |
-21 |
|
|
|
WTOL |
°C |
54 |
54 |
54 |
54 |
54 |
54 |
|
|
G Συνθήκες (-15°CDB/-) |
COPd |
|
2.10 |
2.10 |
2.12 |
2.12 |
2.13 |
2.13 |
|
|
|
Pdh |
kW |
11.1 |
11.1 |
11.9 |
11.9 |
12.6 |
12.6 |
|
|
|
PERd |
% |
84.0 |
84.0 |
84.8 |
84.8 |
85.2 |
85.2 |
|
|
Tbiv (δίτιμη θερμοκρασία) |
COPd |
|
1.93 |
1.93 |
2.05 |
2.05 |
2.13 |
2.13 |
|
|
|
Pdh |
kW |
11.4 |
11.4 |
12.4 |
12.4 |
12.6 |
12.6 |
|
|
|
PERd |
% |
77.2 |
77.2 |
82.0 |
82.0 |
85.2 |
85.2 |
|
|
|
Tbiv |
°C |
-18 |
-18 |
-16 |
-16 |
-15 |
-15 |
|
|
Ονομ. θερμική ισχύς, συμπληρ. απόδοση |
Psup (σε Tdesign -22°C) |
kW |
5.5 |
5.5 |
7.0 |
7.0 |
7.9 |
7.9 |
|
Έξοδος νερού θερμού κλίματος 55°C |
Γενικά |
Ετήσια κατανάλωση ενέργειας |
kWh |
3,696 |
3,696 |
4,104 |
4,104 |
4,362 |
4,362 |
|
|
|
Ƞs (Εποχιακή απόδοση θέρμανσης χώρου) |
% |
156 |
156 |
160 |
160 |
162 |
162 |
|
|
|
Prated στους 2°C |
kW |
11 |
11 |
13 |
13 |
14 |
14 |
|
|
|
Qhe Ετήσια κατανάλωση ενέργειας (GCV) |
Gj |
13.3 |
13.3 |
14.8 |
14.8 |
15.7 |
15.7 |
|
|
Προϋπόθεση Β (2°CDB/1°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
|
|
|
COPd |
|
2.45 |
2.45 |
2.43 |
2.43 |
2.41 |
2.41 |
|
|
|
Pdh |
kW |
11.4 |
11.4 |
12.4 |
12.4 |
13.5 |
13.5 |
|
|
|
PERd |
% |
98.0 |
98.0 |
97.2 |
97.2 |
96.4 |
96.4 |
|
|
C Συνθήκες (7°CDB/6°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
|
|
|
COPd |
|
3.58 |
3.58 |
3.62 |
3.62 |
3.66 |
3.66 |
|
|
|
Pdh |
kW |
7.2 |
7.2 |
7.9 |
7.9 |
8.7 |
8.7 |
|
|
|
PERd |
% |
143.2 |
143.2 |
144.8 |
144.8 |
146.4 |
146.4 |
|
|
D Συνθήκες (12°CDB/11°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
0.96 |
0.96 |
0.96 |
0.96 |
0.96 |
0.96 |
|
|
|
COPd |
|
5.16 |
5.16 |
5.29 |
5.29 |
5.38 |
5.38 |
|
|
|
Pdh |
kW |
5.3 |
5.3 |
5.2 |
5.2 |
5.2 |
5.2 |
|
|
|
PERd |
% |
206.4 |
206.4 |
211.6 |
211.6 |
215.2 |
215.2 |
|
|
Tbiv (δίτιμη θερμοκρασία) |
COPd |
|
2.45 |
2.45 |
2.43 |
2.43 |
2.41 |
2.41 |
|
|
|
Pdh |
kW |
11.4 |
11.4 |
12.4 |
12.4 |
13.5 |
13.5 |
|
|
|
PERd |
% |
98.0 |
98.0 |
97.2 |
97.2 |
96.4 |
96.4 |
|
|
|
Tbiv |
°C |
2 |
2 |
2 |
2 |
2 |
2 |
|
Εξαγωγή νερού μέσου κλίματος 35°C |
Γενικά |
SCOP |
|
4.38 |
4.38 |
4.45 |
4.45 |
4.56 |
4.56 |
|
|
|
Ετήσια κατανάλωση ενέργειας |
kWh |
5,189 |
5,189 |
5,797 |
5,797 |
6,345 |
6,345 |
|
|
|
Ƞs (Εποχιακή απόδοση θέρμανσης χώρου) |
% |
172 |
172 |
175 |
175 |
179 |
179 |
|
|
|
Prated στους -10°C |
kW |
11 |
11 |
13 |
13 |
14 |
14 |
|
|
|
Qhe Ετήσια κατανάλωση ενέργειας (GCV) |
Gj |
18.7 |
18.7 |
20.9 |
20.9 |
22.8 |
22.8 |
|
|
|
Κατηγορία εποχ. απόδοσης θέρμανσης χώρου |
|
A++ |
A++ |
A++ |
A++ |
A++ |
A++ |
|
|
A Συνθήκες (-7°CDB/-8°CWB) |
COPd |
|
3.07 |
3.07 |
2.85 |
2.85 |
2.99 |
2.99 |
|
|
|
Pdh |
kW |
9.7 |
9.7 |
11.1 |
11.1 |
12.2 |
12.2 |
|
|
|
PERd |
% |
122.8 |
122.8 |
114.0 |
114.0 |
119.6 |
119.6 |
|
|
Β Συνθήκες (2°CDB/1°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
|
|
|
COPd |
|
4.15 |
4.15 |
4.24 |
4.24 |
4.30 |
4.30 |
|
|
|
Pdh |
kW |
6.3 |
6.3 |
7.0 |
7.0 |
7.4 |
7.4 |
|
|
|
PERd |
% |
166.0 |
166.0 |
169.6 |
169.6 |
172.0 |
172.0 |
|
|
Προϋπόθεση C (7°CDB/6°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
0.95 |
0.95 |
1.0 |
1.0 |
0.95 |
0.95 |
|
|
|
COPd |
|
5.86 |
5.86 |
6.24 |
6.24 |
6.35 |
6.35 |
|
|
|
Pdh |
kW |
4.5 |
4.5 |
4.5 |
4.5 |
5.0 |
5.0 |
|
|
|
PERd |
% |
234.4 |
234.4 |
249.6 |
249.6 |
254.0 |
254.0 |
|
|
D Συνθήκες (12°CDB/11°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
0.94 |
0.94 |
0.94 |
0.94 |
0.94 |
0.94 |
|
|
|
COPd |
|
7.88 |
7.88 |
8.12 |
8.12 |
8.12 |
8.12 |
|
|
|
Pdh |
kW |
5.3 |
5.3 |
5.3 |
5.3 |
5.3 |
5.3 |
|
|
|
PERd |
% |
315.2 |
315.2 |
324.8 |
324.8 |
324.8 |
324.8 |
|
|
Tol (όριο λειτουργίας θερμοκρασίας) |
COPd |
|
2.80 |
2.80 |
2.53 |
2.53 |
2.72 |
2.72 |
|
|
|
Pdh |
kW |
11.0 |
11.0 |
12.5 |
12.5 |
14.5 |
14.5 |
|
|
|
PERd |
% |
112.0 |
112.0 |
101.2 |
101.2 |
108.8 |
108.8 |
|
|
|
TOL |
°C |
-10 |
-10 |
-10 |
-10 |
-10 |
-10 |
|
|
|
WTOL |
°C |
35 |
35 |
35 |
35 |
35 |
35 |
|
|
Tbiv (δίτιμη θερμοκρασία) |
COPd |
|
2.80 |
2.80 |
2.53 |
2.53 |
2.72 |
2.72 |
|
|
|
Pdh |
kW |
11.0 |
11.0 |
12.5 |
12.5 |
14.5 |
14.5 |
|
|
|
PERd |
% |
112.0 |
112.0 |
101.2 |
101.2 |
108.8 |
108.8 |
|
|
|
Tbiv |
°C |
-10 |
-10 |
-10 |
-10 |
-10 |
-10 |
|
|
Συμπληρ. απόδοση ονομαστικής εξόδου ισχύος |
Psup (σε Tdesign -10°C) |
kW |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
|
Εξαγωγή νερού ψυχρού κλίματος 35°C |
Γενικά |
Ετήσια κατανάλωση ενέργειας |
kWh |
9,295 |
9,295 |
10,249 |
10,249 |
11,108 |
11,108 |
|
|
|
Ƞs (Εποχιακή απόδοση θέρμανσης χώρου) |
% |
151 |
151 |
151 |
151 |
157 |
157 |
|
|
|
Prated στους -22°C |
kW |
15 |
15 |
16 |
16 |
18 |
18 |
|
|
|
Qhe Ετήσια κατανάλωση ενέργειας (GCV) |
Gj |
33.5 |
33.5 |
36.9 |
36.9 |
40.0 |
40.0 |
|
|
Προϋπόθεση A (-7°CDB/-8°CWB) |
COPd |
|
3.09 |
3.09 |
3.20 |
3.20 |
3.39 |
3.39 |
|
|
|
Pdh |
kW |
9.0 |
9.0 |
9.7 |
9.7 |
10.8 |
10.8 |
|
|
|
PERd |
% |
123.6 |
123.6 |
128.0 |
128.0 |
135.6 |
135.6 |
|
|
Β Συνθήκες (2°CDB/1°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
1.0 |
1.0 |
1.0 |
1.0 |
0.97 |
0.97 |
|
|
|
COPd |
|
4.45 |
4.45 |
4.45 |
4.45 |
4.68 |
4.68 |
|
|
|
Pdh |
kW |
5.6 |
5.6 |
5.6 |
5.6 |
7.1 |
7.1 |
|
|
|
PERd |
% |
178.0 |
178.0 |
178.0 |
178.0 |
187.2 |
187.2 |
|
|
Προϋπόθεση C (7°CDB/6°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
0.94 |
0.94 |
0.94 |
0.94 |
0.94 |
0.94 |
|
|
|
COPd |
|
6.24 |
6.24 |
6.46 |
6.46 |
6.75 |
6.75 |
|
|
|
Pdh |
kW |
4.5 |
4.5 |
4.5 |
4.5 |
4.6 |
4.6 |
|
|
|
PERd |
% |
249.6 |
249.6 |
258.4 |
258.4 |
270.0 |
270.0 |
|
|
Προϋπόθεση D (12°CDB/11°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
0.94 |
0.94 |
0.94 |
0.94 |
0.94 |
0.94 |
|
|
|
COPd |
|
7.84 |
7.84 |
7.98 |
7.98 |
8.19 |
8.19 |
|
|
|
Pdh |
kW |
5.2 |
5.2 |
5.3 |
5.3 |
5.3 |
5.3 |
|
|
|
PERd |
% |
313.6 |
313.6 |
319.2 |
319.2 |
327.6 |
327.6 |
|
|
Tol (όριο θερμοκρασίας λειτουργίας) |
COPd |
|
2.13 |
2.13 |
2.10 |
2.10 |
2.10 |
2.10 |
|
|
|
Pdh |
kW |
11.8 |
11.8 |
13.5 |
13.5 |
13.5 |
13.5 |
|
|
|
PERd |
% |
85.2 |
85.2 |
84.0 |
84.0 |
84.0 |
84.0 |
|
|
|
TOL |
°C |
-22 |
-22 |
-22 |
-22 |
-22 |
-22 |
|
|
|
WTOL |
°C |
35 |
35 |
35 |
35 |
35 |
35 |
|
|
Προϋπόθεση G (-15°CDB/-) |
COPd |
|
2.67 |
2.67 |
2.43 |
2.43 |
2.40 |
2.40 |
|
|
|
Pdh |
kW |
12.1 |
12.1 |
13.4 |
13.4 |
14.6 |
14.6 |
|
|
|
PERd |
% |
106.8 |
106.8 |
97.2 |
97.2 |
96.0 |
96.0 |
|
|
Tbiv (δισθενής θερμοκρασία) |
COPd |
|
2.49 |
2.49 |
2.36 |
2.36 |
2.40 |
2.40 |
|
|
|
Pdh |
kW |
13.1 |
13.1 |
13.7 |
13.7 |
14.6 |
14.6 |
|
|
|
PERd |
% |
99.6 |
99.6 |
94.4 |
94.4 |
96.0 |
96.0 |
|
|
|
Tbiv |
°C |
-18 |
-18 |
-16 |
-16 |
-15 |
-15 |
|
|
Συμπληρ. απόδοση ονομαστικής εξόδου ισχύος |
Psup (σε Tdesign -22°C) |
kW |
2.7 |
2.7 |
2.5 |
2.5 |
4.5 |
4.5 |
|
Εξαγωγή νερού θερμού κλίματος 35°C |
Γενικά |
Ετήσια κατανάλωση ενέργειας |
kWh |
2,496 |
2,496 |
2,779 |
2,779 |
3,136 |
3,136 |
|
|
|
Ƞs (Εποχιακή απόδοση θέρμανσης χώρου) |
% |
233 |
233 |
237 |
237 |
236 |
236 |
|
|
|
Prated στους 2°C |
kW |
11 |
11 |
13 |
13 |
14 |
14 |
|
|
|
Qhe Ετήσια κατανάλωση ενέργειας (GCV) |
Gj |
8.99 |
8.99 |
10.0 |
10.0 |
11.3 |
11.3 |
|
|
Β Συνθήκες (2°CDB/1°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
|
|
|
COPd |
|
3.40 |
3.40 |
3.25 |
3.25 |
3.22 |
3.22 |
|
|
|
Pdh |
kW |
11.1 |
11.1 |
12.4 |
12.4 |
12.7 |
12.7 |
|
|
|
PERd |
% |
136.0 |
136.0 |
130.0 |
130.0 |
128.8 |
128.8 |
|
|
Προϋπόθεση C (7°CDB/6°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
|
|
|
COPd |
|
5.67 |
5.67 |
5.70 |
5.70 |
5.73 |
5.73 |
|
|
|
Pdh |
kW |
7.6 |
7.6 |
8.4 |
8.4 |
9.3 |
9.3 |
|
|
|
PERd |
% |
226.8 |
226.8 |
228.0 |
228.0 |
229.2 |
229.2 |
|
|
Tbiv (δισθενής θερμοκρασία) |
COPd |
|
3.40 |
3.40 |
3.25 |
3.25 |
3.44 |
3.44 |
|
|
|
Pdh |
kW |
11.1 |
11.1 |
12.4 |
12.4 |
12.2 |
12.2 |
|
|
|
PERd |
% |
136.0 |
136.0 |
130.0 |
130.0 |
137.6 |
137.6 |
|
|
|
Tbiv |
°C |
2 |
2 |
2 |
2 |
4 |
4 |
|
|
D Συνθήκες (12°CDB/11°CWB) |
Cdh (θέρμανση υποβάθμισης) |
|
0.94 |
0.94 |
0.94 |
0.94 |
0.94 |
0.94 |
|
|
|
COPd |
|
7.60 |
7.60 |
7.78 |
7.78 |
8.03 |
8.03 |
|
|
|
Pdh |
kW |
5.2 |
5.2 |
5.3 |
5.3 |
5.3 |
5.3 |
|
|
|
PERd |
% |
304.0 |
304.0 |
311.2 |
311.2 |
321.2 |
321.2 |
Σημειώσεις |
(1) - Συνθήκη 1: ψύξη Ta 35°C - LWE 18°C (DT = 5°C) θέρμανση Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(1) - Συνθήκη 1: ψύξη Ta 35°C - LWE 18°C (DT = 5°C) θέρμανση Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(1) - Συνθήκη 1: ψύξη Ta 35°C - LWE 18°C (DT = 5°C) θέρμανση Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(1) - Συνθήκη 1: ψύξη Ta 35°C - LWE 18°C (DT = 5°C) θέρμανση Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(1) - Συνθήκη 1: ψύξη Ta 35°C - LWE 18°C (DT = 5°C) θέρμανση Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(1) - Συνθήκη 1: ψύξη Ta 35°C - LWE 18°C (DT = 5°C) θέρμανση Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
|
(2) - Συνθήκη 2: ψύξη Ta 35°C - LWE 7°C (DT = 5°C) θέρμανση Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) |
(2) - Συνθήκη 2: ψύξη Ta 35°C - LWE 7°C (DT = 5°C) θέρμανση Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) |
(2) - Συνθήκη 2: ψύξη Ta 35°C - LWE 7°C (DT = 5°C) θέρμανση Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) |
(2) - Συνθήκη 2: ψύξη Ta 35°C - LWE 7°C (DT = 5°C) θέρμανση Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) |
(2) - Συνθήκη 2: ψύξη Ta 35°C - LWE 7°C (DT = 5°C) θέρμανση Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) |
(2) - Συνθήκη 2: ψύξη Ta 35°C - LWE 7°C (DT = 5°C) θέρμανση Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) |